Our technical assistance services on Alstom® ALSPA™ P320 DCS


Alstom® and related trademarks are the property of their respective owners. IEPC Energy is an independent provider and is not affiliated with, sponsored by, or endorsed by Alstom®.

ALSPA™ P320 DCS technical assitance & maintenance in  operational conditions (MOC)


IEPC Energy offers its services to maintain your ALSPA™ P320 DCS Series 5 & 6 in operational conditions:

  • Preventive maintenance of the entire ALSPA™ DCS, according to the P320 Series 5 and P320 Series 6 maintenance guides
  • Analysis and resolution of network problems: Wireshark analysis, monitoring, and configuration of Hirschmann switches
  • Analysis and resolution of synchronization system problems: GPS clock configuration and NTP service
  • Analysis and resolution of problems related to cell head PLCs and field PLCs (MFC3000, C80-75, X20, CE2000)
  • Updates and modifications of the HMI database
  • Updates and modifications of supervision synoptics
  • Analysis and resolution of Historian problems: archiving failures, inability to access archived data, etc.
  • Modification of PLC programs, modification of PLC sequences.

Retrofits & migrations from ALSPA™ P320 DCS to other DCS


With its strong skills and experience, IEPC Energy offers you its expertise for the migration of your ALSPA™ system to other systems. Please contact us for any need you may have related to your ALSPA™ P320 DCS.

A quick overview of the ALSPA™ P320 DCS system


ALSPA™ architecture and networks

Alstom® DCS the ALSPA™ P320, consists of a distributed HMI, the CentraLog™, connected to the programmable logic controlers via a unit network, S8000 via copper and/or fiber optics, based on the TCP/IP protocol. The S8000 network is configured either as a bus, redundant or not, or as a ring, redundant or not.

The PLC controllers are connected to the field controllers and I/O racks via the field network, redundant or not:

  • The F8000, used in Series 5, is based on the WorldFIP protocol.
  • The E8000, used in Series 6, is based on the EPL (Ethernet Power Link) protocol.

ALSPA™ P320 PLCs, field controlers and I/O racks

The mastercell PLCs used in the ALSPA™ system differ depending on the series:

  • The ALSPA™ P320 Series 5 uses GE-Fanuc C80-75 PLCs connected to the CE2000 I/O racks and field controlers
  • The ALSPA™ P320 Series 6 uses MFC3000 PLCs, a specific Alstom®/GE® configuration of AdLink® cPCI PLCs. They are connected to the BnR® X20 or CE2000 I/O racks and field controllers, depending on the configuration.

In both series, the mastercell PLCs, field controllers, and I/O racks can be either single (simplex) or redundant (duplex).

ALSPA™ P320 HMI suite CentraLog™ and engineering tolos ControCad™

In Series 5 and 6, the CentraLog™ runs on Windows. It is available in two configurations:

  • Configured in C30, the supervision (CVS), data exchange (CIS), archiving (Historian or HDSR), and communication with external systems (Gateways) functions are distributed across different operator stations.
  • Configured in C10, all Centralog functions are concentrated on a single operator station.

The engineering tool, ControCad™, is used to modify and update the HMI supervision database and diagrams. It is also used to configure and program the PLCs, as well as the I/O and communications with external systems (Modbus, IEC104, etc.).